Do I Need Sprinklers in a 3 Family Nyc

Automatic sprinkler systems play a very important function in making buildings safe for occupants, since they are one of the kickoff lines of defense if a burn breaks out, forth with fire alarms. A properly-designed automatic sprinkler system can quench pocket-sized fires by itself, and buys additional time for the burn down department if at that place is a major fire. Due to their life-saving potential, automated sprinkler systems are subject field to various building codes and standards, ensuring they will conduct out their role properly.


Protect your property with a fire sprinkler organisation.

Contact Us


Before any residential edifice in New York City is canonical for occupancy, compliance with the following is required:

NYC Building Code, where most requirements are fix forth in Chapter 9 (Fire Protection Systems) and Appendix Q (Modified National Standards for Automatic Sprinkler, Standpipe, Fire Pump and Burn down Alarm Systems).

New York Urban center Burn down Code
  1. NFPA thirteen – Standard for the Installation of Sprinkler Systems
  2. NFPA 13D – Standard for the Installation of Sprinkler Systems in Ane- and Two-Family Dwellings and Manufactured Homes
  3. NFPA 13R – Standard for the Installation of Sprinkler Systems in Depression-Rise Residential Occupancies

It is important to note that NFPA Standards xiii, 13D and 13R are subject to additional requirements and modifications in the example of New York City, and they are explained in particular in Appendix Q of the NYC Building Lawmaking.

When Are Automatic Sprinkler Systems Required in Residential Buildings?

As a full general rule, all Group R occupancies in New York City must be equipped with an automatic sprinkler system. The system must encompass all burn down areas in the building, and the requirement applies for any mixed occupancies where Group R predominates. There are merely three types of residential buildings where the NYC code makes automatic sprinkler systems optional:

  1. Detached i-family dwellings.
  2. Detached two-family unit dwellings.
  3. Townhouses, besides known as multiple single-family dwellings.

The merely requirement for the automatic sprinkler system to be optional is that these structures must not be taller than three stories in a higher place grade, and each dwelling unit must take independent means of egress. If either of these conditions is non met, the sprinkler system becomes mandatory.

It is as well important to note than whatever automatic sprinkler systems in these types of buildings must run across NFPA 13D and any applicable modifications in Appendix Q of the NYC Building Lawmaking. This applies regardless of whether the sprinkler system is optional or mandatory.

For larger residential buildings, up to half-dozen stories high, the applicable document is NFPA 13R, and Appendix Q modifications apply here as well.

Automatic Sprinkler Systems in Residential Outdoor Areas

In residential outdoor areas like balconies, decks and patios, sprinkler systems are required when the ii post-obit atmospheric condition are met:

  • Automatic sprinklers are already mandatory for the building itself.
  • The edifice is of Type V construction.

Wall sprinklers are permitted, as long equally they are located betwixt 1 and 6 inches below structural members. For exterior balconies and decks built from wood joists, the maximum distance immune for wall sprinklers is 14 inches below the deck.

H2o Supply Requirements for Residential Sprinkler Systems

Automated sprinkler systems in residential settings tin use the primary h2o supply, sharing it with domestic fitting and appliances. Information technology is only necessary to see some extra requirements established in the NYC Edifice Code to guarantee system reliability.

  • The offset and most of import requirement is coming together the NFPA 13 standard, which applies for all sprinkler systems installed in the USA regardless of calibration. Proceed in mind that the NFPA 13R or 13D may likewise apply depending on the type of building.
  • Standpipes are non required if the total number of sprinkler heads per connection stays beneath 20.
  • The h2o supply must be sized to provide the total domestic demand and sprinkler head demand simultaneously.

In residential occupancies where a burn warning organisation is mandatory, all valves involved in the water supply for the automated sprinkler organisation must be equipped with a sensor and monitored electrically. The only cases where a central monitoring station is non mandatory are one- and two-family dwelling units, besides as automated sprinkler systems with less than 20 sprinkler heads.

If a residential building uses elevators, keep in heed that the NYC Building Lawmaking does non allow the use of sprinklers in auto rooms and associated spaces.

Additional Recommendations for Residential Sprinkler Systems

fire sprinkler

The cost of automatic sprinkler systems in new residential constructions can exist optimized if the squad in accuse of blueprint collaborates closely with the architects. Keep in heed that the cost of an automated sprinkler system strongly depends on the sprinkler head count, and architectural features that complicate coverage may increase the number of sprinklers significantly.

  • Extra sprinklers involve more than piping, and increase the required capacity of the main h2o supply.
  • A standpipe may be required if the sprinkler caput count becomes too high, and this increases the number of requirements that must be met by the fire protection system.

Slight architectural modifications often brand it possible to reduce the sprinkler caput count significantly, which reduces installation costs without compromising performance.

Keep in mind that automatic sprinkler systems are inspected by the NYC Section of Buildings, and the building tin't be used legally for its intended occupancy until all inspections have been approved. The sprinkler system is assessed based on the requirements of the NYC Fire Code and Building Code, as well every bit all applicable NFPA codes and their modifications. Make certain yous work with qualified and licensed engineering professionals when dealing with residential sprinkler systems: the installation will guarantee building prophylactic, and the approval process with the NYC Department of Buildings will be carried out without hurdles.

When architectural and fire protection design are carried out in isolation, expensive fire protection systems ofttimes outcome. The use of a Building Information Modeling (BIM) tool can be of great assistance when coordinating both design teams, since they tin visualize how architectural changes affect sprinkler organisation design, and vice-versa.

To reduce fire protection arrangement costs in residential settings, it is very of import to avert situations where standpipes and monitoring systems get mandatory, since costs increase dramatically. Sprinkler systems can be made much less expensive through smart design choices, while still providing safety and meeting the applicable codes.

Editors Note: This postal service was originally published in Apr 2017 and has been revamped and updated for accuracy and comprehensiveness.